How long will your fiber router, NAS, workstation, or refrigerator actually survive a blackout? Vendor stickers quote gross battery Wh or inflated VA numbers while quietly ignoring DC→AC inverter losses, constant idle draw, safe Depth of Discharge (DoD), and Peukert capacity sag on older lead-acid/AGM UPS units compared with LiFePO4 banks. Model realistic outage runtime below before sizing backup hardware.

⚡ DC→AC Physics & Peukert Derating · 100% Client-Side Private Calculator
Real Estimated Runtime
-
Usable AC Energy Delivered
-
Inverter Load Utilization
-
Expected Cycle Lifespan
-
Calculating backup runtime...
Alternative Load Step Total Draw Incl. Idle Real Runtime Status
Orientative notice: Physical estimate assuming healthy cells at 20–25 °C ambient temperature. Aged lead-acid/AGM UPS batteries (>2 years) or heavy sub-1-hour discharge currents experience accelerated Peukert sag and internal resistance losses that can trim real runtime by another 20–35%.

Exact UPS & Battery Runtime Formula

Turning marketing nameplate Wh into actual outlet runtime comes down to four physical losses:

Usable_AC_Wh = Nominal_Wh × Usable_DoD × Peukert_Factor × (Inverter_Eff / 100)

Runtime_Hours = Usable_AC_Wh / (Connected_Load_W + Inverter_Idle_Draw_W)

  • VA vs. Real Watts: Consumer UPS ratings quote apparent power (VA), where continuous real power equals VA × Power_Factor (0.6 – 0.9). A typical budget "1000VA" desktop UPS tops out near 600 W continuous.
  • Inverter idle overhead: Keeping an AC inverter energized burns 10–35 W continuously—so running a 12 W fiber ONT/router through a giant AC inverter often wastes more battery overhead than actual network load.

Verified Physics & Engineering References

Outage Scenario Comparison Table (1,024 Wh Nominal Bank)

Connected Load Average Draw AGM Lead-Acid (1024 Wh gross) LiFePO4 Bank (1024 Wh gross)
Fiber ONT + Wi-Fi router22 W~10.5 hours~22.5 hours
Router + 2-bay NAS + mini-PC65 W~5.2 hours~10.2 hours
Laptop + external monitor + LED lamp110 W~3.1 hours~6.5 hours
Modern home refrigerator (avg cycle)95 W~3.5 hours~7.4 hours
Workstation / heavy gaming rig450 W~42 min (Peukert sag)~1.7 hours

Frequently Asked Questions (FAQ)

Why does an AGM UPS last half as long as a same-Wh LiFePO4 station?
Standard AGM cells only deliver ~50–60% usable DoD cleanly and lose effective capacity sharply at fast discharge rates (Peukert effect), whereas LiFePO4 provides ~90% usable capacity for 3,000+ cycles instead of 250–500.

Which other Syncroma tools complement home backup & energy planning?
Measure individual appliance kWh bills in our Appliance & Homelab Electricity Cost Calculator or model full rooftop solar ROI with Syncroma's Spain Solar Panel ROI Calculator.

Suscribirse Subscribe