Accurately model building envelope energy efficiency and heat loss. Calculate the Thermal Transmittance (U-Value in W/m²K), Total Thermal Resistance (R-Value in m²K/W), and Heat Loss (Watts / kWh) across multi-layer walls, facades, roofs, and insulation assemblies according to international ISO 6946 and CTE DB-HE standards.

1. Wall Structure & Layer Parameters

15 cm
8 cm
1.5 cm

Thermal Performance & Heat Loss Metrics

Thermal Transmittance (U-Value)
0.34 W/m²K Meets High-Efficiency
Total Thermal Resistance (R-Value)
2.94 m²K/W Air films included
Continuous Heat Loss Through Surface
255 Watts 6.1 kWh / day
Insulation & Building Code Rating: Superb insulation. Comfortably complies with modern strict thermal envelope limits.

Common Building Materials Thermal Conductivity (λ) Reference

Building Material Conductividad (λ en W/mK) Thickness for R = 2.5 m²K/W Insulating Tier
Poliuretano / PIR Rígido 0.024 W/mK 6.0 cm Peak thermal performance
Poliestireno Extruido (XPS) 0.034 W/mK 8.5 cm Moisture resistant
Lana de Roca / Mineral 0.035 W/mK 8.8 cm Fireproof & acoustic barrier
Ladrillo Hueco Tradicional 0.490 W/mK 122 cm (1.2 metros) Structural only
Hormigón Armado 1.740 W/mK 435 cm (4.3 metros) Severe thermal bridge

ISO 6946 Thermal Transmittance Mathematical Formulas

U-Value calculations for composite building envelopes adhere strictly to ISO 6946 standards:

R_capa = Espesor [m] / Conductividad_λ [W/mK]
R_total = R_si + Σ(R_capa_i) + R_se [m²K/W]
Valor_U = 1 / R_total [W/m²K]
Pérdida_Calor [W] = Valor_U × Superficie [m²] × ΔT [°C]
  • Surface Film Air Resistances (R_si + R_se): For horizontal heat flux across external walls, standard values are R_si = 0.13 m²K/W (interior) and R_se = 0.04 m²K/W (exterior).
  • Diminishing Returns Law: The first 5 cm of insulation deliver 70% of heat flux reduction. Adding insulation exhibits asymptotic returns.
  • Thermal Bridges (Ψ): This tool models 1D plane transmittance. Slab edges and window jambs require external insulation overlap to eliminate condensation.

Frequently Asked Questions: U-Value & Thermal Insulation

1. What is the U-Value (Thermal Transmittance) and why is lower better?

U-Value quantifies heat energy escaping per square meter per degree Kelvin temperature difference (W/m²K). A lower U-Value means better insulation, slashing heating demand in winter and cooling load in summer.

2. What are the maximum U-values permitted under building codes?

Spanish building codes enforce maximum wall U-values from 0.56 W/m²K (Zone A, warm) down to 0.31 W/m²K (Zone E, cold mountains). Passivhaus mandates under 0.15 W/m²K.

3. What is the difference between conductivity (λ), resistance (R), and U-Value?

Conductivity (λ) is an intrinsic material property. Resistance (R = thickness / λ) measures heat opposition for a specific layer. The U-Value is the inverse of the sum of all resistances: U = 1 / R_total.

4. Which insulation material is most compact per centimeter?

PIR/Polyurethane boards lead with λ = 0.024 W/mK, followed by XPS (0.034) and mineral wool (0.035). PIR delivers 40% higher insulation in space-constrained retrofits.