(🇪🇸 Ver la versión en español de esta Calculadora de Aerotermia vs Gas aquí)
Calculate the real annual heating cost in Spain comparing an Air-to-Water Heat Pump (Aerotermia) against a Regulated Natural Gas Boiler (TUR 2) and Direct Electric Radiators, including Spanish utility taxes (21% VAT, IEE 5.11%, hydrocarbon tax) and realistic CapEx payback years.
Exact Thermodynamic & Billing Formulas
Sales brochures often compare gas and electricity per billed kWh while omitting boiler combustion losses, fixed standing charges, and Spanish utility taxes. Here is the exact equation used by the simulator above:
Cost_HeatPump = E_elec_heatpump × P_elec × (1 + IEE) × (1 + VAT)
E_gas_billed = Q_thermal / Eta_boiler
Cost_Gas_TUR = [ E_gas_billed × (P_gas_var + Hydroc_Tax) + (Fixed_mo × 12) ] × (1 + VAT)
Parity_Elec_Rate = Cost_Gas_Unit_Thermal × SCOP / ((1 + IEE) × (1 + VAT))
Payback (years) = Extra_Upfront_CapEx / (Cost_Gas_TUR - Cost_HeatPump)
Verified Official Benchmarks (Spain, November 2026)
- Regulated Natural Gas TUR Q4 2026 (BOE-A-2026-20389): Effective October 1, 2026, Spanish pre-tax regulated rates set TUR 1 (≤ 5,000 kWh/yr) at ~€3.83/mo fixed + €0.0525/kWh, and TUR 2 (5,001–15,000 kWh/yr for home heating) at ~€8.17/mo fixed + €0.0504/kWh. Official BOE Resolution and tariff summary on Eleia Energía.
- Spain PVPC 2.0TD Electricity Average (Nov 2026): Provisional regulated daytime average sits near €0.215/kWh (Red Eléctrica e·sios Portal and CosteEnergía Nov 2026 PVPC index).
- IDAE Heat Pump & Thermostat Standards: Spain's national energy institute (IDAE Nov 2026 Aerotermia Guide & IDAE Energy Efficiency Guide) recommends 20–21 °C daytime setpoints, noting each extra +1 °C adds roughly 7% to heating demand. Spanish electricity excise tax (5.11269632%) is governed by Law 38/1992 (BOE-A-1992-28741).
Real-World Scenario Comparison (9,000 kWh Thermal Demand/Year)
| Emitter Configuration | Efficiency (SCOP / η) | Billed Energy | Annual Cost (Incl. Tax) | Best Fit |
|---|---|---|---|---|
| Heat Pump + Underfloor (35 °C) | SCOP 4.4 | 2,045 kWh elec | €559 / yr | New builds & deep retrofits |
| Heat Pump + Low-Temp Radiators | SCOP 3.8 | 2,368 kWh elec | €649 / yr | Strong with Solar PV / off-peak EV tariff |
| Gas Condensing Boiler (TUR 2) | η 88% | 10,227 kWh gas | €771 / yr | Wins ROI if heat pump quote is inflated |
| High-Temp Heat Pump (60 °C) | SCOP 2.8 | 3,214 kWh elec | €879 / yr | Avoid without solar or cheap off-peak plan |
| Direct Electric Heaters | COP 1.0 | 9,000 kWh elec | €2,462 / yr | Occasional guest rooms / holiday flats only |
Frequently Asked Questions
Why does heat pump payback stretch out compared to Spain's regulated TUR 2 gas?
Because Spain's regulated TUR 2 gas tariff remains capped by RDL 25/2026 at ~€0.0504/kWh pre-tax while average grid electricity sits around €0.215/kWh—a 4.2x grid spark spread. Heat pumps crush gas on operating bills whenever SCOP stays above 3.8 AND you combine them with solar self-consumption (Spain Solar Panel ROI Calculator) or off-peak 2.0TD rates (Spain 2.0TD Electricity Bill Calculator).
How sensitive is SCOP to radiator water temperature?
Extremely sensitive. Raising supply flow temperature from 35 °C (underfloor heating, SCOP ~4.3) to 60 °C (legacy cast-iron radiators, SCOP ~2.8) increases annual electricity consumption by 53.6% for the exact same indoor heat output.